RFC 8971 | BFD for VXLAN | December 2020 |
Pallagatti, et al. | Informational | [Page] |
This document describes the use of the Bidirectional Forwarding Detection (BFD) protocol in point-to-point Virtual eXtensible Local Area Network (VXLAN) tunnels used to form an overlay network.¶
This document is not an Internet Standards Track specification; it is published for informational purposes.¶
This document is a product of the Internet Engineering Task Force (IETF). It represents the consensus of the IETF community. It has received public review and has been approved for publication by the Internet Engineering Steering Group (IESG). Not all documents approved by the IESG are candidates for any level of Internet Standard; see Section 2 of RFC 7841.¶
Information about the current status of this document, any errata, and how to provide feedback on it may be obtained at https://www.rfc-editor.org/info/rfc8971.¶
Copyright (c) 2020 IETF Trust and the persons identified as the document authors. All rights reserved.¶
This document is subject to BCP 78 and the IETF Trust's Legal Provisions Relating to IETF Documents (https://trustee.ietf.org/license-info) in effect on the date of publication of this document. Please review these documents carefully, as they describe your rights and restrictions with respect to this document. Code Components extracted from this document must include Simplified BSD License text as described in Section 4.e of the Trust Legal Provisions and are provided without warranty as described in the Simplified BSD License.¶
"Virtual eXtensible Local Area Network (VXLAN)" [RFC7348] provides an encapsulation scheme that allows the building of an overlay network by decoupling the address space of the attached virtual hosts from that of the network.¶
One use of VXLAN is in data centers interconnecting virtual machines (VMs) of a tenant. VXLAN addresses the requirements of the Layer 2 and Layer 3 data-center network infrastructure in the presence of VMs in a multi-tenant environment by providing a Layer 2 overlay scheme on a Layer 3 network [RFC7348]. Another use is as an encapsulation for Ethernet VPN [RFC8365].¶
This document is written assuming the use of VXLAN for virtualized hosts and refers to VMs and VXLAN Tunnel End Points (VTEPs) in hypervisors. However, the concepts are equally applicable to non-virtualized hosts attached to VTEPs in switches.¶
In the absence of a router in the overlay, a VM can communicate with another VM only if they are on the same VXLAN segment. VMs are unaware of VXLAN tunnels, because a VXLAN tunnel is terminated on a VTEP. VTEPs are responsible for encapsulating and decapsulating frames exchanged among VMs.¶
The ability to monitor path continuity -- i.e., perform proactive continuity check (CC) for point-to-point (p2p) VXLAN tunnels -- is important. The asynchronous mode of BFD, as defined in [RFC5880], is used to monitor a p2p VXLAN tunnel.¶
In the case where a Multicast Service Node (MSN) (as described in Section 3.3 of [RFC8293]) participates in VXLAN, the mechanisms described in this document apply and can, therefore, be used to test the continuity of the path between the source Network Virtualization Endpoint (NVE) and the MSN.¶
This document describes the use of the Bidirectional Forwarding Detection (BFD) protocol to enable monitoring continuity of the path between VXLAN VTEPs that are performing as VNEs, and/or between the source NVE and a replicator MSN using a Management VXLAN Network Identifier (VNI) (Section 4). All other uses of the specification to test toward other VXLAN endpoints are out of scope.¶
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in BCP 14 [RFC2119] [RFC8174] when, and only when, they appear in all capitals, as shown here.¶
Figure 1 illustrates a scenario with two servers: each hosting two VMs. The servers host VTEPs that terminate two VXLAN tunnels with VNI number 100 and 200, respectively. Separate BFD sessions can be established between the VTEPs (IP1 and IP2) for monitoring each of the VXLAN tunnels (VNI 100 and 200). Using a BFD session to monitor a set of VXLAN VNIs between the same pair of VTEPs might help to detect and localize problems caused by misconfiguration. An implementation that supports this specification MUST be able to control the number of BFD sessions that can be created between the same pair of VTEPs. This method is applicable whether the VTEP is a virtual or physical device.¶
At the same time, a service-layer BFD session may be used between the tenants of VTEPs IP1 and IP2 to provide end-to-end fault management; this use case is outside the scope of this document. In such a case, for VTEPs, the BFD Control packets of that session are indistinguishable from data packets.¶
For BFD Control packets encapsulated in VXLAN (Figure 2), the inner destination IP address SHOULD be set to one of the loopback addresses from 127/8 range for IPv4 or to one of IPv4-mapped IPv6 loopback addresses from ::ffff:127.0.0.0/104 range for IPv6.¶
In most cases, a single BFD session is sufficient for the given VTEP to monitor the reachability of a remote VTEP, regardless of the number of VNIs. BFD control messages MUST be sent using the Management VNI, which acts as the control and management channel between VTEPs. An implementation MAY support operating BFD on another (non-Management) VNI, although the implications of this are outside the scope of this document. The selection of the VNI number of the Management VNI MUST be controlled through a management plane. An implementation MAY use VNI number 1 as the default value for the Management VNI. All VXLAN packets received on the Management VNI MUST be processed locally and MUST NOT be forwarded to a tenant.¶
BFD packets MUST be encapsulated and sent to a remote VTEP as explained in this section. Implementations SHOULD ensure that the BFD packets follow the same forwarding path as VXLAN data packets within the sender system.¶
BFD packets are encapsulated in VXLAN as described below. The VXLAN packet format is defined in Section 5 of [RFC7348]. The value in the VNI field of the VXLAN header MUST be set to the value selected as the Management VNI. The outer IP/UDP and VXLAN headers MUST be encoded by the sender, as defined in [RFC7348].¶
The BFD packet MUST be carried inside the inner Ethernet frame of the VXLAN packet. The choice of destination Media Access Control (MAC) and destination IP addresses for the inner Ethernet frame MUST ensure that the BFD Control packet is not forwarded to a tenant but is processed locally at the remote VTEP. The inner Ethernet frame carrying the BFD Control packet has the following format:¶
The destination UDP port is set to 3784 and the fields of the BFD Control packet are encoded as specified in [RFC5881].¶
Once a packet is received, the VTEP MUST validate the packet. If the packet is received on the Management VNI and is identified as a BFD Control packet addressed to the VTEP, then the packet can be processed further. Processing of BFD Control packets received on a non-Management VNI is outside the scope of this specification.¶
The received packet's inner IP payload is then validated according to Sections 4 and 5 in [RFC5881].¶
Support for echo BFD is outside the scope of this document.¶
IANA has assigned a single MAC address of the value 00-52-02 from the "Unassigned (small allocations)" block of the "IANA Unicast 48-bit MAC Addresses" registry as follows: the "Usage" field is "BFD for VXLAN". The "Reference" is this document.¶
Security issues discussed in [RFC5880], [RFC5881], and [RFC7348] apply to this document.¶
This document recommends using an address from the internal host loopback addresses 127/8 range for IPv4, or an IP4-mapped IPv6 loopback address from the ::ffff:127.0.0.0/104 range for IPv6, as the destination IP address in the inner IP header. Using such an address prevents the forwarding of the encapsulated BFD control message by a transient node, in case the VXLAN tunnel is broken, in accordance with [RFC1812].¶
The use of IPv4-mapped IPv6 addresses has the same property as using the IPv4 network 127/8. Moreover, the IPv4-mapped IPv6 addresses' prefix is not advertised in any routing protocol.¶
If the implementation supports establishing multiple BFD sessions between the same pair of VTEPs, there SHOULD be a mechanism to control the maximum number of such sessions that can be active at the same time.¶
The authors would like to thank Jeff Haas of Juniper Networks for his reviews and feedback on this material.¶
The authors would also like to thank Nobo Akiya, Marc Binderberger, Shahram Davari, Donald E. Eastlake 3rd, Anoop Ghanwani, Dinesh Dutt, Joel Halpern, and Carlos Pignataro for the extensive reviews and the most detailed and constructive comments.¶